V 2003

Fixed bolt for structural bolted glass - cylindrical head - for installation from the outside - Cap Nut Options

Features
  • Façade or glass roof
  • Cylindrical drilling
  • Contact washer (railing application)
Product code V2003
Materials
Stainless steel AISI 316
Dimensions / Type
* Tailored products and solutions on demand

Glasses
Clear selection
Related accessories

Fixed bolt, cylindrical head. Installation from the outside (blind access).

Cylindrical drilling.
M14 standard axle.
Length: 65 mm (standard). ⌀ axis : M14 / lenght axis 65 mm / lenght L 40 / lenght X 120±2

V2003 has a contact washer, you can therefore use this fitting for a railing application (this solution is not validated by the french CEBTP testing center).

No technical evaluation for V2003.

Glass

Performances

Suggested mounting instruction

A – Classic mounting
Insert parts No.2/3/4/5 into the glass hole. Mount the second contact washer No.4, external plate No.1, and bolt No.9 and tighten
to 20 Nm ( 15 ft-lb ) for monolithic glass and 10 Nm ( 7.5 ft-lb ) for laminated glass. Thread on nut No.6 and apply washer No.7.
Insert the threaded axle into the support with spacer E ( available on request ), see technical page. Adjust the depth. Mount the second washer No.7, lock washer No.8, and nut No.10. Tighten to 60 Nm ( 45 ft-lb ) using a 22 mm wrench.

B – Blind mounting: installation from the outside ( no access to the structure )
Mount nut No.6 and washer No.7 onto parts No.2/3/4/5. Insert the threaded axle into the support with spacer E ( available on request ),
see technical page. Adjust the depth. Mount the second washer No.7, lock washer No.8, and nut No.10. Tighten to 60 Nm ( 45 ft-lb ) using a 22 mm wrench. Set the glass onto the assembly, be careful not to put unprotected glass edges in contact with bare metal parts. Mount parts No.1/4 and 9 onto parts No.2/3/4/5 and tighten to 20 Nm ( 15 ft-lb ) for monolithic glass and 10 Nm ( 7.5 ft-lb ) for laminated glass using a 10 mm wrench and a 5 mm hex key.

SADEV reco mmends using thread locking compound whenever possible.

Inscrivez-vous pour être informé des actus SADEV.

Nous nous engageons à ne pas diffuser votre adresse e-mail à des tiers.

Activité(s) :

Vous êtes intéressés par :

Politique de confidentialité

Merci pour votre inscription.

Register to be informed of SADEV news.

We undertake not to distribute your e-mail address to third parties.

Activity(ies):

Interested by:

Privacy policy

Thank you for your suscription.

Pin It on Pinterest